Bellingham + Stanley Density Meter DSG40 with Temperature Control

Share:


Bellingham + Stanley Density Meter DSG40 with Temperature Control

Bellingham + Stanley Density Meter DSG40 with Temperature Control

The DSG Density Meter Series from Bellingham + Stanley answers a call from customers looking for highly reliable, premium quality instruments to complete a suite of instrumentation from a brand they trust. DSG Series density meters from Bellingham + Stanley are available in 2 unique models offering great flexibility as well as ease of use. 

  • FDA 21 CFR Part 11 compatible 
  • Peltier Temperature Control 
  • Excellent reproducibility 
  • 20 second read time 
  • Strong air pump for thorough cleaning 
  • Standard Leur connectors
  • METHODS based
  • Easy to clean


Simple to use. Easy to clean. Accurate Results.

DSG Series Density Meters from Bellingham + Stanley are available in 2 models, offering users the choice to hone in the precision, accuracy, and resolution depending on application. 

Having an accurate density meter that produces reliable results is only part of the equation. Your instrumentation also needs to be simple to use, easy to clean and offer superior traceability. The DSG Series features a large and vibrant capacitive touchscreen, and intuitive GUI from the makers of ADP Polarimeters and RFM Refractometers. This colour coded interface guides users through common tasks and administrative setup procedures with ease. 

A powerful internal air pump and integrated desiccant means the DSG Series has no need for external devices for venting after cleaning, so your precious bench space isn’t taken up by needless peripherals.

Peltier Temperature Control and precision ventilation ports give rapid temperature stabilisation, whilst synergy between hardware and software give accurate results in as little as 15 seconds.


Certified Reference Materials for Density Meters

Certified Reference Fluid used for verifying the performance of digital density meters such as the DSG Series Density Meter from Bellingham + Stanley.


Specifications
 

Physical Specifications
Measuring System
Oscillating U-tube with reference oscillator for enhanced drift protection  
Temperature Control
Intelligent Peltier temperature control system 
Wetted Parts
Borosilicate glass, PTFE
Pressure
0 – 10 bar (0 – 145 PSI)
Sample Size
Approx. 2ml
Air Drying
Integrated air pump and humidity sensor
User Interface
Full colour, 7”, capacitive touchscreen with optional mouse & keyboard support
Memory
100,000+ Readings (4GB expandable memory)
Interfaces
Serial Interface, USB, LAN
Application Compliance
European & American Pharmacopoeia & various ASTM & ISO standards. Electronic Signatures
Power
90-265 VAC; 50/60 Hz; 150 VA max
Humidity
< 85% not condensing
Ambient Temp
Temperature 10 °C — 35 °C
Weight
8.8kg + 0.3kg dry air cartridge (approximate)
Dimensions
430 x 290 x 300mm (WxDxH)
Certificates
Conformity or optional Certificate of Calibration on request


Measurement Specifications
Range
0 – 3 g/cm3
METHODS
Density (g/cm3), Specific Gravity, Sucrose %w/w (°Brix), Ethanol (%w/w, %v/v), API, user request
Reading Type
Single shot (discreet)
Reading Time
15 seconds (not including temperature stabilization time) 
Resolution
0.0001 g/cm3
Accuracy
0.0001 g/cm3
Precision (Reproducibility)
0.0001 g/cm3
Temperature Accuracy
±0.05 °C
Temp. Reproducibility
±0.02 °C
Temperature Range
10 – 95 °C
Temperature Resolution
±0.01 °C
Temp. Stabilisation Time
Smart stabilisation based on sample detected